Foundation settlement
Elastic settlement, excavation heave and vertical soil reaction modulus. Boussinesq–Steinbrenner layer approximation · rigid or flexible contact · SI units
Load a saved calculation
Calculation method & reference states
Loading settlement and preceding heave
Excavation heave uses the unloading/reloading modulus. The two-stage option reloads up to the released effective base pressure with that modulus, then uses the primary loading modulus. The secant option uses one loading modulus for the complete loading stage.
The spring reference is the excavated state. Enter the full structural service load; the excavation is calculated separately.
The pressure split is an approximation for matching footprints. It does not track preconsolidation, local yielding or the full three-dimensional stress path.
Scope of the elastic model
Integrated Boussinesq displacements with Steinbrenner layer differences. Rigid contact enforces uniform settlement; flexible contact uses uniform pressure. The layered solution is approximate and does not enforce exact interface compatibility.
Groundwater stays hydrostatic and unchanged. Heave below groundwater assumes a water-supported excavation. Dewatering, consolidation time, yielding and plate bending require a separate analysis.
References: Steinbrenner (1934), bibliographic reference · Cuira & Simon (2009) · Mayne & Poulos (1999)
Found this tool useful?
koplemo is free, with no ads and no sign-up. It is kept running by the engineers who use it.
Payment handled by Stripe. We never see your card details.
Payment handled by Stripe. You can cancel at any time; write to [email protected] if you need help.
About this tool
Calculates the elastic settlement of shallow foundations on horizontally layered ground, with rigid or flexible contact. Vertical displacements are integrated from the Boussinesq solution over the foundation area, layer by layer in the Steinbrenner manner.
Optionally the heave of a preceding excavation is calculated with the unloading-reloading modulus, followed by reloading and primary loading, with a fixed groundwater level and hydrostatic uplift. The tool also returns the vertical soil reaction modulus for structural models.
Inputs can be saved and loaded as JSON, and the results exported as a PDF report.
Worked example
Related tools
Free to use, no sign-up. Results are for checking and preliminary design; verify them for your project. Questions or ideas: [email protected].