Toppling stability

Flexural toppling of steep layers in bending, or block toppling of columns on a stepped base (Direct toppling tab), with water, seismic load, rock bolts and shotcrete. Close the window to see the kinematic stereonet. Stability analyses: Planar sliding stability · Wedge sliding stability · Toppling stability · Kinematic analysis

Worked example: Block toppling · Worked example: Flexural toppling

Slope face
ψf°
αf°
ψs°
Strength and limits
φ°
Lat. sliding± °
Lat. toppling± °
Discontinuities
SetDip [°]Dip dir. [°]φ [°]
φ per set overrides the global φ (e.g. bedding with clay infill). Wedges use the lower φ of the two planes.
Format
Set window°
SetDip/ddnK
Display
Net
Loading...
Planar sliding
Which face direction is best?
Same discontinuities and face dip, all face dip directions. Useful for road cuts that turn, quarry benches and tunnel portals.

About this tool

Toppling analysis of a rock slope with steep discontinuities that dip into the face. The page opens the stability window of the rock slope kinematics tool for flexural toppling; block toppling is on the Direct toppling tab. Both use the same slope and joint orientations as the kinematic stereonet check.

Block toppling follows the limit equilibrium method of Goodman and Bray (1976), as presented by Hoek and Bray (1981) and Wyllie and Mah (2004): columns of width Δx stand on a stepped base, and working down from the top column each one is stable, topples or slides. Flexural toppling treats each layer as a cantilever fixed on a basal failure plane that fails when the bending tension reaches the tensile strength σ_t of the rock (Aydan and Kawamoto 1992).

Inputs are the slope height, the column width, the dip of the base planes and of the stepped base line, the friction angles on the base and on the sides of the columns, and for flexural toppling the tensile strength. Water in the slope, a seismic coefficient, a surface load, rock bolts and shotcrete on the toe column can be added. The design basis is a factor of safety or EN 1997-1.

Results are the factor of safety on tan φ (with σ_t reduced by the same factor), the mode of every column (stable, topple, bend or slide), the force at the toe, a 3D view and a cross-section of the columns, a sensitivity chart and a Monte Carlo probability of failure.

What is the difference between flexural and block toppling?

In flexural toppling continuous steep layers bend and break in tension, like cantilevers. In block toppling the columns are separated by cross joints and rotate as rigid blocks about their toe.

When is toppling possible?

Steep planes must dip into the slope within about ±20° of the opposite of the face dip direction. Flexural toppling also needs interlayer slip, dip ≥ (90° − face dip) + φ (Goodman 1980); block toppling needs a base plane flatter than φ under the columns.

Worked example

Related tools

Free to use, no sign-up. Results are for checking and preliminary design; verify them for your project. Questions or ideas: [email protected].