Slope stability (LEM)
Factor of safety of a soil or rock slope by limit equilibrium: Bishop, Janbu, Spencer, Morgenstern-Price and six more methods, grid, refine and cuckoo searches with optimised non-circular surfaces, layers in Mohr-Coulomb, undrained or Hoek-Brown strength (with a disturbed zone behind the excavation), water table, tension crack, loads and seismic load, anchors, soil nails, geotextiles and piles, and Eurocode 7 design approaches 1, 2 and 3. Draw the section or import it from DXF.
Materials
Regions
Excavation lines (Hoek-Brown D)
Water
Loads and seismic
| x1 | x2 | q1 | q2 | Dir. | Act. |
|---|
| x | Fx | Fy | Act. |
|---|
Tension crack
Supports (anchors, nails, geotextiles, piles)
Eurocode 7 (design approach)
Analysis
Slices of the critical surface
Found this tool useful?
koplemo is free, with no ads and no sign-up. It is kept running by the engineers who use it.
Payment handled by Stripe. We never see your card details.
Payment handled by Stripe. You can cancel at any time; write to [email protected] if you need help.
About this tool
The tool computes the factor of safety of a soil or rock slope in plane strain by the method of slices. Every classic method is solved as one set of General Limit Equilibrium equations: Ordinary (Fellenius), Bishop simplified, Janbu simplified, corrected and generalized, Corps of Engineers 1 and 2, Lowe-Karafiath, Spencer and Morgenstern-Price with a half-sine or constant interslice function. Spencer and Morgenstern-Price satisfy both force and moment equilibrium.
The section is a set of material regions: draw them in the page (with snapping to vertices, edges and a grid, and a coordinate table that takes values pasted from Excel) or import a DXF drawing, where each closed polyline is a region named after its layer and an open line the water table. Materials are Mohr-Coulomb (c', φ', optionally growing with depth), undrained (su, also growing with depth), su/σ'v ratio, generalised Hoek-Brown for a rock mass (σci, mi, GSI, D), weight only or impenetrable. The Hoek-Brown disturbance factor D can apply only within a depth d of excavation lines drawn along the cut face, in full or tapering, as in KoFEA's finite elements. Pore pressures come from a water level, a phreatic line (with Hu), piezometric lines or ru; water above the ground acts as a ponded load. Distributed and line loads on the ground, pseudo-static seismic coefficients kh and kv and a tension crack (a depth or a crack line, dry or filled with water) are included.
Supports are drawn from their head to their end: end-anchored anchors, tiebacks with a bonded length, soil nails with a face plate, geotextiles, piles and user-defined force curves, alone or as a row. Where a slip surface crosses one, its force (the least of its tensile, pull-out and stripping resistance, or a pile's shear) acts on that slice, as a load (active) or divided by the factor of safety like the soil's strength (passive). A concrete pile's shear resistance can come from its section by EN 1992-1-1 (concrete class, diameter, hoops and bars), or any pile's can be given. The analysis gives either the factor of safety with characteristic values or a Eurocode 7 check by design approach 1 (DA1-1 and DA1-2), 2 or 3: the page shows every partial factor of each combination before the run, they can be changed, and the result is the over-design factor ODF of each combination and method, the least one governing.
Three searches find the critical surface. The grid search tries a grid of centres with radii from the circle touching the ground to the one reaching the bottom of the model, plus the circles through the toe, the crest and the other corners of the ground, and refines the grid around the best centre. The refine search tries circles between divisions of the ground and divides again where the best of them start and end. The cuckoo search looks for non-circular surfaces (polylines) with Lévy flights. The optimisation then moves the vertices of the lowest surfaces, as a polyline, to a lower factor, for example along a weak layer. A circular or polyline slip surface can also be given. The results show the factor of every method, the critical surface with its slices, the lowest surfaces (and the grid) coloured by their factors, and the forces of every slice.
The analysis engine is verified on published benchmarks, which open from the Examples menu: the ACADS referee problems (Giam and Donald 1989), within 1 % of published by-method values for the searched cases and 0.0 % on the given weak-layer surface with Morgenstern-Price, and Taylor's vertical cut in undrained clay (stability number 3.83). Save writes the model as a .kofea file.
Sources: the methods of slices as summarised by Duncan, Wright and Brandon (2014, Soil Strength and Slope Stability, 2nd ed.), including the treatment of reinforcement forces as known loads or divided by the factor of safety; Morgenstern and Price (1965); Spencer (1967); cuckoo search after Yang and Deb (2009); Hoek-Brown after Hoek, Carranza-Torres and Corkum (2002); benchmark slopes from Giam and Donald (1989).
Which method should I use?
Spencer or Morgenstern-Price: they satisfy force and moment equilibrium. Bishop simplified is close to them on circles and is a good check; Janbu simplified and Ordinary are usually lower (conservative). The tool reports every method chosen on the same model, each with its own critical surface.
Why is my factor slightly lower than in another program?
Searched factors depend on the surfaces tried. This tool includes the circles through the corners of the ground (toe and crest) and refines the grid, and so often finds a slightly lower circle than an entry-exit search; on a given surface the factors agree.
Can I analyse a rock slope with Hoek-Brown?
Yes. Choose Hoek-Brown in the material dialog and give σci, mi and GSI; each slice base gets the curved envelope at its own normal stress. For blast damage, give D and a depth d and draw an excavation line along the cut face: D then applies only within d of it. A search takes about four to seven times longer than with Mohr-Coulomb, so the server allows a smaller one.
How does the Eurocode 7 check work?
Choose design approach 1, 2 or 3 in the Eurocode 7 group. Each combination factors the loads (on their effect or on the permanent loads), the soil's strength and the supports' resistances by the factors in the table, and the analysis gives its factor F with those design values; the over-design factor ODF is F divided by γR;e (and by γG where it acts on the effect), and the slope satisfies the approach where the least ODF is at least 1. The recommended values of EN 1997-1 Annex A are the defaults; change a cell for a national annex.
Can I use non-circular slip surfaces?
Yes. The cuckoo search finds non-circular surfaces (polylines), and the optimisation turns the lowest circles or polylines of any search into a polyline with a lower factor, for example along a weak layer. A polyline can also be given.
Worked example
Related tools
Free to use, no sign-up. Results are for checking and preliminary design; verify them for your project. Questions or ideas: [email protected].