Apparent dip and daylighting in a road cut: worked example

Apparent dip of bedding and three joint sets in the section of a 65° road cut, which planes daylight, and why a daylighting plane can still be safe, by hand and with the free tool.

 Open this example in the tool The link loads all inputs below.

Problem

A road cut will have a face dipping 65° towards 135° (SE). Mapping found bedding and three joint sets. Which of them daylight in the face and could let a block slide out, and how steep do they look in the section drawn for the design report?

PlaneDip [°]Dip direction [°]
Slope face65135
Bedding S040150
Joint J175120
Joint J250320
Joint J335210

A cross-section along the dip direction of the face does not show a plane at its true dip but at its apparent dip, which is smaller unless the plane strikes parallel to the face. The numbers are our own case.

1. Apparent dip

For a plane with dip ψ and dip direction α, cut by a vertical section with azimuth β:

tan ψa = tan ψ · cos(β − α)

Positive ψa means the plane dips towards β, out of a face that looks that way. Here β = 135°:

Planeβ − α [°]cos(β − α)tan ψtan ψaψa [°]
S0 40/150−150.96590.83910.810539.0
J1 75/120150.96593.73213.604974.5
J2 50/320−185−0.99621.1918−1.1872−49.9
J3 35/210−750.25880.70020.181210.3

2. Does each plane daylight?

A plane daylights in the section when it dips out of the face (ψa > 0) and less steeply than the face (ψa < 65°), so that it runs out of the face below the crest.

S0: 0 < 39.0° < 65° → daylights
J1: 74.5° > 65° → dips out of the slope but steeper than the face, does not daylight
J2: −49.9° → dips into the slope, favourable for sliding (check toppling instead)
J3: 0 < 10.3° < 65° → daylights in the section

3. What the section does not show

The apparent dip of J3 is low because its dip direction is 75° off the face: it strikes nearly across the face. A block on J3 would have to slide towards 210°, almost along the face, and the rock on either side holds it. Hoek and Bray limit planar sliding to planes whose dip direction is within about ±20° of the face. S0 (15° off) passes, J3 (75° off) does not.

S0: |150 − 135| = 15° ≤ 20° → planar sliding possible if its true dip, 40°, exceeds φ
J3: |210 − 135| = 75° > 20° → no planar sliding, it can still form a wedge with another set

So the section is right to draw S0 at 39° out of the face, and the design should check S0 for planar sliding. The friction check uses the true dip, 40°, not the apparent one. With φ = 35° for the bedding, 40° > 35° and the block can slide. J3 needs the stereonet: its line of intersection with S0 or J1 may form a wedge.

Result in the tool

Hand calculationToolDifference
S0 apparent dip39.0°, daylights39.0°, daylights in the face0
J1 apparent dip74.5°, steeper than the face74.5°, steeper than the face0
J2 apparent dip−49.9°, into the slope−49.9°, into the slope0
J3 apparent dip10.3°, daylights10.3°, daylights in the face0

The link at the top opens the tool with the face and the four planes. It draws the section along 135° with each plane through the toe or the crest edge, so you can copy the figure into the report.

Your own case

  • The apparent dip answers "how does the plane look in this section". Whether a block can slide is a three-dimensional question: use the Rock slope kinematics tool, which checks planar sliding, wedges and toppling on a stereonet. The planar sliding worked example continues from a case like S0.
  • Enter compass readings as dip, dip direction pairs, one plane per line. Convert strike readings first: with the right-hand rule, dip direction = strike + 90°.
  • For a section in any other direction, enter that azimuth as the slope dip direction. The same formula gives the apparent dip in a tunnel wall or along a borehole log.

References

  • Hoek, E. & Bray, J.W. (1981). Rock Slope Engineering, 3rd ed. Institution of Mining and Metallurgy, London, chapters 3 and 7.
  • Wyllie, D.C. & Mah, C.W. (2004). Rock Slope Engineering: Civil and Mining, 4th ed. Spon Press, London, chapter 2.
  • Priest, S.D. (1993). Discontinuity Analysis for Rock Engineering. Chapman & Hall, London.

Worked example by Martin Hostnik, updated 2026-11-21. Results are for checking and preliminary design; verify them for your project. Questions or a correction: [email protected].