Ground anchor design in sand over marl: worked example

Bond length, tendon, ground cone, proof and lock-off loads of a 4-strand tieback bonded in sand and marl, to EN 1997-1 A1:2013, by hand and with the free tool.

 Open this example in the tool The link loads all inputs below.

Problem

A 6 m high soldier pile wall is held by one row of permanent strand anchors at 2.0 m spacing. The service load of one anchor is FServ,k = Pk = 350 kN. The anchor head is 3.0 m below the ground, inclined 25° below the horizontal, with a 7.0 m free length and an 8.0 m bond length drilled at 150 mm. Check the grout–ground bond, the tendon, the grout–tendon bond and the ground cone to EN 1997-1:2004 + A1:2013, find the bond length the ground needs, and set the proof and lock-off loads. A rock bolt check closes the example.

Fill, 0–4.0 mγ = 18 kN/m³ (no bond in this layer)
Medium dense sand, 4.0–7.5 mγ = 19 kN/m³, qs = 200 kPa (FHWA range 100–250 kPa)
Marl (weak rock), below 7.5 mγ = 22 kN/m³, qs = 400 kPa (range 300–800 kPa)
Water table6.5 m below the ground
Tendon4 strands Y1860S7 15.2 mm, At = 4 × 140 = 560 mm², fp0.1k = 1600 MPa, fpk = 1860 MPa
FactorsγE = γServ = 1.35, γa,ULS = 1.1, model factor γRd = 1.4, γs = 1.15

1. Geometry and design load

Top of the bond: z1 = 3.0 + 7.0 sin 25° = 5.96 m; end: z2 = 5.96 + 8.0 sin 25° = 9.34 m
Bond in sand: (7.5 − 5.96)/sin 25° = 3.63 m; in marl: 8.0 − 3.63 = 4.37 m
EULS,d = max(γE Pk, γServ FServ,k) = max(1.35 · 350, 1.35 · 350) = 472.5 kN (EN 1997-1 A1:2013, 8.3)

2. Grout–ground bond

With qs the resistance of a layer is π D qs L. The calculated value stands in for the measured resistance of suitability tests and is divided by the model factor before the partial factor.

Sand: π · 0.15 · 200 · 3.63 = 342 kN; marl: π · 0.15 · 400 · 4.37 = 823 kN; Rcalc = 1166 kN
RULS,k = 1166 / 1.4 = 833 kN; RULS,d = 833 / 1.1 = 757 kN
FoS = Rd/Ed = 757 / 472.5 = 1.60; utilisation 0.62; without partial factors 1166 / 350 = 3.33
Bond length the ground needs: Rcalc = 472.5 · 1.4 · 1.1 = 728 kN = 342 + 188.5 · Lmarl → Lmarl = 2.04 m, Lbond = 3.63 + 2.04 = 5.7 m

3. Tendon, grout and ground cone

Pt0.1k = 560 · 1600 = 896 kN, Ptk = 560 · 1860 = 1042 kN
Rt,d = 896 / 1.15 = 779 kN; FoS = 779 / 472.5 = 1.65
Grout–tendon: 4 · π · 15.2 = 191 mm × 8000 mm × 2.0 MPa / 1.5 = 2037 kN; FoS 4.31
Ground cone, apex at the middle of the bond h = 7.65 m, half angle 30°: single cone 156 m³, per anchor in the row s h² tan 30° = 2.0 · 7.65² · 0.577 = 67.6 m³ (governs); σ′v(7.65 m) = 72 + 66.5 + 3.3 − 11.5 = 130.3 kPa, mean γ′ = 17.0 kN/m³, W = 1151 kN
0.9 W = 1036 kN against the vertical component 472.5 sin 25° = 200 kN: FoS 5.19

The ground cone and the grout are far from governing. The bond (1.60) and the tendon (1.65) are close, which is the usual aim: the tendon should not be much weaker than the ground, otherwise the proof load cannot show the ground resistance. Detailing: free length 7.0 m ≥ 5 m, bond starts 4.5 m beyond the slip surface (≥ max(1.5 m, 6/5)), 6.0 m of ground over the bond (≥ 4.5 m), spacing 2.0 m ≥ max(4 · 0.15, 1.2) m, service load 350 ≤ 0.65 · 1042 = 677 kN.

4. Proof and lock-off loads

Acceptance test, method 1: Pp ≥ γa,acc,ULS EULS,d = 1.1 · 472.5 = 520 kN
Pp ≤ min(0.95 · 896, 0.80 · 1042) = 833 kN: 62 % ✓; lock-off P0 = Pk = 350 kN ≤ 0.60 · 1042 = 625 kN ✓
Datum load Pa = 52 kN. Elastic elongation from Pa to Pp, Et At = 195 000 · 560 = 109.2 MN, with Le = 1.5 m: lower limit 0.8 · 7.0 + 1.5 = 7.1 m → 30.4 mm; Lfree + Le = 8.5 m → 36.4 mm; upper limit 7.0 + 1.5 + 4.0 = 12.5 m → 53.5 mm

Measured readings pasted in the test tab give the apparent free tendon length from the unloading. For example an unloading of 468 kN with a recovery of 43 mm gives Lapp = 109.2 · 43 / 468 = 10.0 m, inside the 7.1–12.5 m band.

5. Rock bolt

A ribbed B500B Ø25 bolt, 4.0 m long in a 45 mm hole, crosses a wedge face 1.6 m behind the face; rock–grout bond 1.0 MPa, grout–bar bond 3.0 MPa, plate 250 kN, 1 mm corrosion loss.

Steel: π · 24² / 4 · 500 = 226 kN
Embedded side, 2.4 m beyond the joint: rock–grout π · 0.045 · 1000 = 141 kN/m (weaker than grout–bar 236 kN/m) → 339 kN
Head side: 250 + 141 · 1.6 = 476 kN; Tk = min(226, 339, 476) = 226 kN, the steel governs from 226 / 141 = 1.6 m of anchored length

Hand calculation and tool

Hand calculationTool
Rcalc / RULS,d1166 / 757 kN1166 / 757 kN
FoS bond / tendon / grout / cone1.60 / 1.65 / 4.31 / 5.191.60 / 1.65 / 4.31 / 5.19
Bond length needed5.7 m5.7 m
Pp / P0520 / 350 kN520 / 350 kN
Elongation band at Pp30.4–53.5 mm30.4–53.5 mm
Rock bolt Tk226 kN226 kN

The calculated bond resistance is a preliminary estimate. EN 1997-1 bases the anchor resistance on investigation or suitability tests, and every working anchor gets an acceptance test to the proof load.

References

  • EN 1997-1:2004 + A1:2013. Eurocode 7: Geotechnical design – Part 1: General rules (Section 8 Anchors, Annex A).
  • EN 1537:2013. Execution of special geotechnical works – Ground anchors.
  • EN ISO 22477-5:2018. Geotechnical investigation and testing – Testing of geotechnical structures – Part 5: Testing of grouted anchors.
  • Hoek, E., Kaiser, P.K. & Bawden, W.F. (1995). Support of Underground Excavations in Hard Rock. Balkema, Rotterdam.
  • Littlejohn, G.S. & Bruce, D.A. (1977). Rock Anchors – State of the Art. Foundation Publications, Brentwood.
  • Sabatini, P.J., Pass, D.G. & Bachus, R.C. (1999). Ground Anchors and Anchored Systems. FHWA-IF-99-015, Geotechnical Engineering Circular No. 4.

Worked example by Martin Hostnik, updated 2026-11-21. Results are for checking and preliminary design; verify them for your project. Questions or a correction: [email protected].