EPB shield face pressure: wedge–prism worked example

Required face pressure of a 10 m EPB shield in silty sand below the water table: silo load, wedge equilibrium, crown pressure window and EN 1997 DA3, by hand and with the free tool.

 Open this example in the tool The link loads all inputs below.

Problem

An EPB shield of 10 m diameter drives through silty sand with 15 m of cover. The water table is 5 m below the surface, and the chamber is kept closed, so no water flows into it. What crown pressure does the face need, and where is the upper limit?

ShieldD = 10 m, cover to the crown C = 15 m, surface load q = 10 kPa
Groundγ = 20 kN/m³ above the water table, γsat = 21 kN/m³ below it, c′ = 5 kPa, φ′ = 30°
Watertable 5 m below the surface, hydrostatic (closed chamber, no seepage)
Modelwedge–prism with K1 = 0.8 in the prism and K2 = 0.4 on the wedge sides (Anagnostou & Kovári 1996), face taken as a 10 × 10 m square
Chambersupport medium 12 kN/m³, water force × 1.05, margin +30 kPa, blow-out limit 0.9 σv

The method is the wedge–prism limit equilibrium of Horn (1961) as developed by Anagnostou and Kovári (1994, 1996). The design follows EN 1997-1:2004, Design Approach 3. The numbers are our own case.

1. Design values (DA3)

tan φ′d = tan 30° / 1.25 = 0.4619 → φ′d = 24.79°,   c′d = 5 / 1.25 = 4.0 kPa
surface load (variable): qd = 1.3 · 10 = 13 kPa,   γ′ = 21 − 10 = 11 kN/m³ below the water table

2. Wedge and prism at θ = 57°

The tool searches the inclination θ of the slip plane. The largest required force is found at θ = 57°, so the hand check uses that angle:

wedge length L = D / tan 57° = 10 / 1.540 = 6.494 m
prism 10 × 6.494 m: silo radius r = B L / (2 (B + L)) = 64.94 / 32.99 = 1.969 m
a = K1 tan φ′d / r = 0.8 · 0.4619 / 1.969 = 0.1877 1/m

Janssen's silo solution is applied layer by layer, σv(z) = (γ − c/r)/a · (1 − e−az) + σv,0 e−az:

top 5 m (γ = 20): (20 − 4.0/1.969)/0.1877 = 95.73 kPa;   e−0.1877·5 = 0.3912
  σ′v at the water table = 95.73 · 0.6088 + 13 · 0.3912 = 63.36 kPa
next 10 m (γ′ = 11): (11 − 2.032)/0.1877 = 47.78 kPa;   e−0.1877·10 = 0.1531
  σ′v on the wedge = 47.78 · 0.8469 + 63.36 · 0.1531 = 50.16 kPa (the total overburden is 320 kPa: arching carries most of it)
prism load V = 50.16 · 10 · 6.494 = 3 258 kN
wedge weight W = 11 · 10 · 10 · 6.494 / 2 = 3 572 kN
slip plane area A = B D / sin θ = 100 / 0.8387 = 119.24 m²
one side face: T = c′ D L/2 + K2 tan φ′d (σ′v D L/2 + γ′ L D²/6)
  = 4.0 · 32.47 + 0.4 · 0.4619 · (50.16 · 32.47 + 11 · 6.494 · 16.67) = 129.9 + 520.9 = 650.8 kN

3. Required support force

Equilibrium of the wedge along and normal to the slip plane, with the support force S′ horizontal:

S′ = [ (W + V)(sin θ − cos θ tan φ′d) − c′d A − 2T ] / (cos θ + sin θ tan φ′d)
  = [ 6 829.5 · (0.8387 − 0.5446 · 0.4619) − 4.0 · 119.24 − 1 301.6 ] / (0.5446 + 0.8387 · 0.4619)
  = (4 010.0 − 477.0 − 1 301.6) / 0.9320 = 2 231.2 / 0.9320 = 2 394 kN
s′d = S′ / D² = 23.9 kPa   (without partial factors: 11.8 kPa at θ = 62°)

4. Crown pressure window

The support force over the face must carry S′d and the water force × 1.05. The pressure in the chamber grows by 12 kN/m³ from the crown down. Pore pressure: 100 kPa at the crown, 200 kPa at the invert, 150 kPa on average.

pcrown ≥ s′d + 1.05 · ū − γs D/2 = 23.9 + 157.5 − 60 = 121.4 kPa (also ≥ 1.05 · 100 = 105 kPa)
minimum with the margin: 121.4 + 30 = 151 kPa at the crown, 211 kPa at the axis, 271 kPa at the invert
total overburden at the crown: 10 + 20 · 5 + 21 · 10 = 320 kPa → maximum 0.9 · 320 = 288 kPa

Running at the minimum, 151 kPa, the effective support provided is 151 + 60 − 157.5 = 53.9 kPa, so FoS = Rd/Ed = 53.9 / 23.9 = 2.25. Most of it comes from the margin and the medium gradient; without the margin the face would be exactly at FoS = 1.

5. Other methods

Vermeer, Ruse & Marcher (2002): Nγ = 1/(9 tan 24.79°) − 0.05 = 0.1906; s′ = 11 · 10 · 0.1906 − 4.0 / 0.4619 = 21.0 − 8.7 = 12.3 kPa
Leca & Dormieux (1990), one-cone upper bound: Nγ = 0.152 at an axis angle of 37°; s′ = 11 · 10 · 0.152 − 8.7 = 8.1 kPa

The wedge–prism value is the highest, as expected for limit equilibrium with silo theory. The upper-bound cone gives an unsafe bound, and the Vermeer formula is a fit to finite element results.

Result in the tool

Hand calculationToolDifference
Critical θ, wedge length57°, 6.494 m57.0°, 6.49 m0 %
σ′v on the wedge50.16 kPa50.2 kPa0 %
V / W3 258 / 3 572 kN3 258 / 3 572 kN0 %
Shear on both side faces1 301.6 kN1 302 kN0 %
s′d23.9 kPa23.9 kPa0 %
Crown pressure window151 – 288 kPa151 – 288 kPa0 %
FoS = Rd/Ed at 151 kPa2.252.250 %
Vermeer / Leca–Dormieux12.3 / 8.1 kPa12.3 / 8.1 kPa0 %

Your own case

  • If the chamber does not keep the water out, choose "Flow into the chamber" and a head drop. The page then solves the 3D seepage towards the face and the required support rises, here to about 38 kPa for Δh = 3 m.
  • For a conventional face below the water table, the seepage forces can double the required support. Try the face bolting page with and without advance drainage.
  • K1 and K2 matter. DAUB uses K2 = (K0 + Ka)/2; a lower K1 gives less arching and a higher pressure.
  • For a jointed rock face use the face wedge stability tool instead; it checks wedges between joint planes.

Worked example by Martin Hostnik, updated 2026-11-21. Results are for checking and preliminary design; verify them for your project. Questions or a correction: [email protected].