Face bolting design

Number, length and overlap of face bolts for conventional tunnelling in soil and weak ground: wedge–prism with silo theory and seepage forces, bond on both sides of the slip plane, EN 1997 DA3. Shield face pressure (slurry and EPB) · Face bolting design · All methods · Rock faces with joints: Face wedge stability

Excavation
Method
Face
Dm
Bm
Hm
Wedge
Cover Cm
Surface qkPa
Ground
Behaviour
γkN/m³
γsatkN/m³
c′kPa
φ′°
cukPa
Ncrit-
K1 prism-
K2 wedge-
Groundwater
Depthm
Seepage
Head drop Δhm
Slurry: the filter cake seals the face, water pressure hydrostatic.
Open face: the face drains, seepage forces from a 3D flow field.
km/s
Drained lengthm
Shield pressure
MarginkPa
γ supportkN/m³
Water ×-
Blow-out ×σv
Operating pcrownkPa
Face bolts
Number-
Lengthm
Min. overlapm
Drill hole Ømm
Bond τkPa
Bolt TkkN
EN 1997
Basis
γφ′ / γc′
γcu-
γQ-
γa bolts-
EN 1997-1:2004 Annex A, DA3: factored ground strength, permanent actions × 1.0. Water pressures are not factored (shield: water force × factor above).
Project information
Name
Description
Design basis

Wedge–prism (Horn 1961; Anagnostou & Kovári 1994, 1996): a wedge in front of the face with an inclined slip plane at θ, loaded by a prism up to the surface. The vertical stress on the wedge follows silo theory (Janssen) with K1 and the shear on the prism sides; the side faces of the wedge carry c′ + K2σ′z tan φ′. The required support force S′(θ) comes from the equilibrium of the wedge along and normal to the slip plane; the largest over θ governs. A circular face is replaced by a square (side D or equal area), a horseshoe by its width × height. Undrained ground: total stresses with cu, φ = 0.

Seepage: steady 3D flow in homogeneous isotropic ground (finite differences, half model), water table constant (recharge), far boundaries hydrostatic, bottom impermeable, the lined tunnel behind the face impermeable. The face has the head of the chamber (EPB with a head drop) or atmospheric pressure (open face); advance drainage keeps the face head over a length ahead of the face. Seepage forces −γw∇h act on the wedge (horizontal and vertical) and, as a change of the effective unit weight, on the prism (Anagnostou & Kovári 1996). A slurry shield and a closed EPB chamber give hydrostatic water and buoyant unit weights.

Shield: the support force over the face must carry S′d plus the water force × factor; with the pressure gradient γsupport of the chamber this gives the minimum crown pressure, which is also at least the water pressure at the crown; then the margin is added (CETU 2022, DAUB 2016). The maximum is the blow-out factor × the total overburden at the crown. FoS = Rd/Ed = provided / required effective support; FoS without partial factors is the strength reduction factor at the operating pressure (without the margin).

Face bolts: bolts spread evenly over the face, each crossing the slip plane at x = z·L/H; capacity min(Tk, τπd·lfront, τπd·lbehind)/γa at the minimum overlap (front = Tk with plates). FoS = Rd/Ed is the smallest ratio of bolt force to required force over all wedges.

Checks: Vermeer, Ruse & Marcher (2002) s = γD(1/(9 tan φ′) − 0.05) − c′ cot φ′ for φ′ ≥ 20°; Leca & Dormieux (1990) kinematic upper bound with one cone, Nγ maximised numerically, cohesion by corresponding states; Broms & Bennermark (1967) σT = σv,axis − Ncritcu. These do not include seepage. EN 1997-1:2004 Annex A, DA3: γφ′ = γc′ = 1.25, γcu = 1.4, γQ = 1.3 (CETU 2022 uses the same factors on the ground strength).

About this tool

Face bolts (usually glass fibre tubes, grouted) reinforce the ground ahead of a conventionally excavated face and are cut away by each round. This page checks them against the wedge–prism mechanism of Horn and Anagnostou–Kovári: every bolt that crosses the slip plane of a wedge holds it with the lower of its tensile capacity, the bond in front of the plane (or the plate) and the bond behind it.

The check is made at the end of a round, with the minimum overlap left ahead of the face, and over every inclination of the slip plane, because a flat wedge may pass behind short bolts. The result is FoS = Rd/Ed, the number of bolts needed, the factor of safety over the round and charts against the number of bolts.

Below the water table the 3D seepage towards the open face adds large forces on the wedge; advance drainage over a length ahead of the face can be switched on to see its effect.

Why is the overlap so important?

At the end of a round the bolts are shortest. A wedge whose slip plane lies behind the remaining bolt length is not held at all, so the overlap, not the full length, governs.

Which bond should I use?

Use pull-out tests on site where possible. Typical grout–soil bond values for face bolts in silts and clays are 50 to 200 kPa, higher in dense sand and gravel.

Related tools

Free to use, no sign-up. Results are for checking and preliminary design; verify them for your project. Questions or ideas: [email protected].