Planar sliding of a rock slope: worked example
Factor of safety of a 20 m rock cut sliding on a 35° joint with a water-filled tension crack (Hoek & Bray method), by hand and with the free tool, plus rock bolts.
Open this example in the tool The link loads all inputs below.
Problem
A 20 m high rock cut has a face dipping 60° towards 135° and a horizontal crest. A persistent joint set dips 35° in the same direction (135°), so it daylights in the face and a block can slide on it. A vertical tension crack opens 5 m behind the crest. After heavy rain the crack is half full of water. What is the factor of safety, and how much bolt force is needed for FS = 1.3?
| Slope height H | 20 m |
| Face dip ψf / dip direction | 60° / 135° |
| Upper slope | horizontal (0°) |
| Sliding plane dip ψp / dip direction | 35° / 135° |
| Rock unit weight γ | 26 kN/m³ |
| Joint strength (Mohr–Coulomb) | c = 25 kPa, φ = 35° |
| Tension crack behind the crest b | 5 m, 50 % filled with water (γw = 9.81 kN/m³) |
The plane strikes parallel to the face, so the two-dimensional solution of Hoek & Bray (1981) and Wyllie & Mah (2004, chapter 6) applies, per metre run of slope. The tool computes the true 3D block; with a block width B = 1 m and a plane parallel to the face it gives the same numbers.
1. Kinematics
The plane daylights (ψp = 35° < ψf = 60°), its dip direction is within ±20° of the face, and ψp is not smaller than φ = 35°. Planar sliding is kinematically possible; the joint plots on the edge of the critical zone of the Markland test.
2. Geometry of the block
Depth of the tension crack:
Weight per metre (crack in the upper surface):
Length of the sliding surface:
3. Water forces
4. Factor of safety
With a dry crack (U = V = 0) the same block has FS = (505.0 + 2547.6 · 0.700) / 1783.8 = 1.28. Half a crack of water takes away about 17 % of the margin, which is why drainage is usually the cheapest stabilisation.
5. Rock bolts
Three rows of bolts, 150 kN each at 2 m horizontal spacing, give T = 3 · 150 / 2 = 225 kN/m. They are installed 15° below horizontal, into the slope, so they make an angle ψT + ψp = 50° with the sliding direction. As active (tensioned) bolts, they add to the normal force and reduce the driving force:
Solving the same equation for FS = 1.3 gives the required bolt force T ≈ 327 kN/m, for example four rows of 165 kN bolts at 2 m spacing.
Result in the tool
| Hand calculation | Tool | |
|---|---|---|
| Weight W | 3110 kN/m | 3110 kN |
| Uplift U / crack water V | 416.8 / 86.8 kN/m | 417 / 87 kN |
| FS, half-filled crack | 1.06 | 1.06 |
| FS, dry crack | 1.28 | 1.28 |
| FS with 225 kN/m active bolts | 1.22 | 1.22 |
| Bolt force for FS 1.3 | ≈ 327 kN/m | 327 kN/m |
In the tool you can switch the tension crack to Critical (minimum FS), try the Barton–Bandis criterion instead of c and φ, add a seismic coefficient, check the case with EN 1997-1 partial factors, or run the sensitivity and probabilistic tabs on φ and the water level. For a real slope use the true block width B; the tool then also accounts for a plane that does not strike exactly parallel to the face.
References
- Hoek, E. & Bray, J.W. (1981). Rock Slope Engineering, 3rd ed. Institution of Mining and Metallurgy, London.
- Wyllie, D.C. & Mah, C.W. (2004). Rock Slope Engineering: Civil and Mining, 4th ed. Spon Press, chapter 6.
Worked example by Martin Hostnik, updated 2026-11-11. Results are for checking and preliminary design; verify them for your project. Questions or a correction: [email protected].