Flexural toppling of a rock slope: worked example

Layers dipping into a 12 m cut bend as cantilevers: kinematic test, 11 columns from the crest to the toe, factor of safety 1.43 and its sensitivity to the tensile strength.

 Open this example in the tool The link loads all inputs below.

Problem

A 12 m high cut in thinly bedded phyllite faces east: the face dips 65° towards 090° and the ground above the crest is level. The layers dip steeply into the slope, 70° towards 270°, and are about 2 m thick between the more open joints. Layers like these do not rotate as rigid blocks: they bend back like cantilevers and crack across near their base. How safe is the cut against flexural toppling, and how much does the answer depend on the tensile strength of the rock?

Slope height H12 m
Face dip / dip direction65° / 090°, upper slope horizontal
Layers, J170° / 270° (into the slope)
Column (layer) width Δx2 m (t in the tool)
Basal failure planeθ0 = 12° steeper than the column bases
Rock unit weight γ26 kN/m³
Friction on the bases and between the layersφp = φd = 30°, no cohesion, dry
Tensile strength of the layers in bendingσt = 0.5 MPa

The method extends the column-by-column limit equilibrium of Goodman & Bray (1976) to columns that fail in bending, after Aydan & Kawamoto (1992) and Adhikary et al. (1997). It works per metre run of the slope, on a section in the dip direction of the face. The numbers are our own case.

1. Kinematics

For flexural toppling the layers must dip into the slope, within about 20° of the direction opposite the face (here exactly opposite), and be steep enough to slip on each other as they bend (Goodman 1989):

(90° − ψf) + φd = 25° + 30° = 55° ≤ 70° → flexural toppling possible

Kinematics only says that the layers can move. Whether they do depends on their weight, their friction and their tensile strength, which the limit equilibrium below adds.

2. Column geometry

The column bases are normal to the layers, so they dip out of the face at ψp = 90° − 70° = 20° and the columns lean towards the face by the same 20°. The basal failure plane, along which the layers crack, rises at ψb = ψp + θ0 = 32°, so each base is a step b higher than the one below:

a1 = Δx tan(ψf − ψp) = 2 · tan 45° = 2.000 m
a2 = Δx tan(ψp − ψs) = 2 · tan 20° = 0.728 m
b = Δx tan(ψb − ψp) = 2 · tan 12° = 0.425 m
below the crest: yn = n (a1 − b) = 1.575 n → 1.575, 3.150, 4.725, 6.300 m
above the crest: yn = yn−1 − a2 − b = yn−1 − 1.153 m

Column 5 straddles the crest. Its upslope side reaches the ground at 7.005 m, and from there the columns get 1.153 m shorter each until column 11, which is only 0.09 m high. The weight of a column is W = γ Δx y, for example 26 · 2 · 7.005 = 364.3 kN/m for column 5, and 2109.6 kN/m for all eleven.

3. Column by column at the limit

A column that bends is a cantilever fixed on the basal failure plane. It fails when the tension at its base reaches σt. Taking moments about the base gives the force needed from the column below (the formula as the tool uses it):

bending: Pn−1,f = [ Pn (Mn − ⅔ Δx tan φd) + (W/6)(3 yn sin ψp − Δx cos ψp) − σt Δx² / 6 ] / (Ln + ⅓ Δx tan φd)
sliding: Pn−1,s = Pn − W (tan φp cos ψp − sin ψp) / (1 − tan φp tan φd)

With the full strength every column is stable and the toe needs no force (column 5 comes closest, with P4,f = −1.8 kN/m). So we look for the factor F by which tan φ and σt must both be divided to bring the toe exactly to the limit. At F = 1.43:

tan φ / F = 0.5774 / 1.4295 = 0.4039,   σt / F = 500 / 1.4295 = 349.8 kPa,   σt Δx² / 6 = 233.2 kNm/m
⅔ Δx tan φd = 0.539 m,   ⅓ Δx tan φd = 0.269 m,   sliding term (0.4039 · 0.9397 − 0.3420) / (1 − 0.1631) = 0.0448
nyn [m]MnLnW [kN/m]PnPn−1,fPn−1,sMode
110.0870.0000.0874.50−659.2−0.2stable
101.2400.5121.24064.50−158.9−2.9stable
92.3931.6652.393124.40−83.1−5.6stable
83.5462.8183.546184.40−47.0−8.3stable
74.6993.9714.699244.30−22.8−11.0stable
65.8525.1245.852304.30−3.9−13.6stable
57.0056.2775.874364.3014.5−16.3bends
46.3006.3004.300327.614.522.0−0.2bends
34.7254.7252.725245.722.0−6.511.0slides
23.1503.1501.150163.811.0−118.03.7slides
11.5751.5750.78781.93.7−220.50.0slides

Mn and Ln are the heights at which the neighbouring columns push, Mn = min(yn, yn+1 + b) and Ln = min(yn, yn−1 − b). Three rows in full:

column 5: P4,f = [0 + 60.71 · (3 · 7.005 · 0.3420 − 2 · 0.9397) − 233.2] / (5.874 + 0.269) = (322.2 − 233.2) / 6.143 = 14.5 kN/m
column 4: P3,f = [14.50 · (6.300 − 0.539) + 54.60 · (6.464 − 1.879) − 233.2] / (4.300 + 0.269) = (83.5 + 250.3 − 233.2) / 4.569 = 22.0 kN/m
column 3: P2,s = 22.02 − 245.7 · 0.0448 = 22.02 − 11.01 = 11.0 kN/m

The six columns above the crest are stable. Columns 5 and 4, the tallest, bend and push on the short columns at the toe, which slide out on their bases. Down the toe the sliding resistance of columns 3, 2 and 1 takes up the push until P0 = 3.67 − 81.9 · 0.0448 = 0.0 at the toe: F = 1.43 is the limit, so

FS = 1.43,   φ needed = arctan(0.4039) = 22.0°

4. How much the tensile strength matters

The tensile term σt Δx² / 6 is what holds the tall columns. Repeating the calculation with other values of σt:

σt [MPa]FSMechanism at the limit
00.509 columns bend
0.251.044 bend, 2 slide
0.51.432 bend, 3 slide
1.01.59all 11 slide

Without tensile strength the layers fail at half the available friction. With 1 MPa they no longer bend at all, and the slope is governed by sliding of the whole stack on the stepped base, which no further tensile strength can improve. In between, FS is very sensitive to σt, a value that is hard to measure for a jointed rock mass. Take it from bending tests or the Brazilian strength of the intact layers and reduce it generously for cracks and weathering, or leave it at zero for a conservative check.

With the EN 1997-1:2004 partial factors of DA3 (γφ' = 1.25 on tan φ and γqu = 1.4 on σt) the tool gives FoS = Rd/Ed = 1.11 ≥ 1, utilisation 0.90.

Result in the tool

Hand calculationToolDifference
Kinematic test55° ≤ 70°, possibleJ1 critical for flexural toppling
Number of columns / step b11 / 0.425 m11 / 0.43 m0 %
Weight per metre2109.6 kN/m2110 kN/m0 %
Columns stable / bending / sliding6 / 2 / 36 / 2 / 3
Largest force between columns22.0 kN/m (between columns 4 and 3)22 kN/m0 %
FS / φ needed1.43 / 22.0°1.43 / 22.0°0 %

The link at the top opens the flexural toppling popup with these inputs. Its Section tab colours each column by its mode, and the sensitivity plot shows the curve of FS against σt from step 4.

Your own case

  • Δx is the spacing of the open joints that cut the rock into independent layers, not the thickness of every thin bed. Thin beds that are welded together bend as one thicker layer.
  • θ0 sets how steeply the basal crack rises through the slope above the column bases. It is seldom known well: check how FS changes between about 10° and 20°.
  • Water in the open joints pushes the layers out and lowers FS quickly. Turn it on and set the fill level.
  • For blocky rock with a second set of cross joints, use block toppling instead. The block toppling worked example uses the same column-by-column approach.

References

  • Goodman, R.E. & Bray, J.W. (1976). Toppling of rock slopes. Proc. Specialty Conference on Rock Engineering for Foundations and Slopes, ASCE, Boulder, Vol. 2, 201–234.
  • Aydan, Ö. & Kawamoto, T. (1992). The stability of slopes and underground openings against flexural toppling and their stabilisation. Rock Mechanics and Rock Engineering 25(3), 143–165.
  • Adhikary, D.P., Dyskin, A.V., Jewell, R.J. & Stewart, D.P. (1997). A study of the mechanism of flexural toppling failure of rock slopes. Rock Mechanics and Rock Engineering 30(2), 75–93.
  • Goodman, R.E. (1989). Introduction to Rock Mechanics, 2nd ed. Wiley, chapter 8.
  • EN 1997-1:2004. Eurocode 7: Geotechnical design, Part 1, Annex A.

Worked example by Martin Hostnik, updated 2026-11-21. Results are for checking and preliminary design; verify them for your project. Questions or a correction: [email protected].