Flexural buckling of a steel tube strut (EC3) worked example

EN 1993-1-1 buckling resistance of a 12 m CHS 406.4x8 S355 excavation strut: class, Ncr, slenderness, chi and Nb,Rd by hand, checked against the free tool.

 Open this example in the tool The tool opens with this strut (CHS 406.4×8, S355, 12 m) as its default; see the Report tab.

Problem

A temporary excavation strut spans 12 m between walings and is pinned at both ends. It is a hot-finished circular hollow section CHS 406.4×8 in S355. What is its design buckling resistance Nb,Rd to EN 1993-1-1:2005?

SectionCHS 406.4 × 8, hot finished (EN 10210-2)
SteelS355, fy = 355 MPa (t ≤ 40 mm), E = 210 GPa
Buckling length Lcr12.0 m about both axes (pinned–pinned)
Partial factorsγM0 = γM1 = 1.0 (recommended values; check your National Annex)

1. Section properties

A = π/4 (D² − d²) = π/4 (406.4² − 390.4²) = 100.1 cm²
I = π/64 (D⁴ − d⁴) = π/64 (406.4⁴ − 390.4⁴) = 19 874 cm⁴, the same about every axis

2. Cross-section class (Table 5.2)

ε = √(235 / 355) = 0.814, ε² = 0.662
d / t = 406.4 / 8 = 50.8: above 70 ε² = 46.3 (class 2 limit), below 90 ε² = 59.6 → Class 3

Class 3 in compression means the full area is effective, so Aeff = A.

3. Elastic critical force and slenderness (6.3.1.2)

Ncr = π² E I / Lcr² = π² · 210 000 · 19 874·10⁴ / 12 000² = 2 860 kN
Npl = A fy = 10 013 · 355 = 3 555 kN
λ̄ = √(A fy / Ncr) = √(3 555 / 2 860) = 1.115

4. Reduction factor χ (6.49)

Hot-finished hollow sections in S355 use buckling curve a, imperfection factor α = 0.21 (Table 6.2).

Φ = 0.5 [ 1 + α (λ̄ − 0.2) + λ̄² ] = 0.5 [ 1 + 0.21 · 0.915 + 1.243 ] = 1.217
χ = 1 / (Φ + √(Φ² − λ̄²)) = 1 / (1.217 + √(1.482 − 1.243)) = 0.586

5. Buckling resistance

Nb,Rd = χ A fy / γM1 = 0.586 · 3 555 / 1.0 = 2 083 kN

Buckling reduces the plastic resistance by 41 %. A design axial force of, say, 1 500 kN gives a utilisation of 1 500 / 2 083 = 0.72 for pure compression.

Result in the tool

Hand calculationTool (Report tab)
A / I100.1 cm² / 19 874 cm⁴100.1 cm² / 19 874 cm⁴
Class33
Ncr,y2 860 kN2 860 kN
λ̄y, curve1.115, a1.115, a
χy0.5860.586

A real strut is never in pure compression: its self-weight, a temperature rise, a construction load or an eccentric connection bends it. The tool checks every pasted row (N, My, Mz, V, T from ZSoil or Excel) with the interaction equations (6.61) and (6.62), Annex A or B, and can add self-weight, snow and temperature to a horizontal strut.

References

  • EN 1993-1-1:2005 + A1:2014, Eurocode 3: Design of steel structures, Part 1-1, clauses 5.5, 6.3.1 and Table 6.2.
  • EN 10210-2:2019, Hot finished steel structural hollow sections, tolerances, dimensions and sectional properties.

Worked example by Martin Hostnik, updated 2026-11-11. Results are for checking and preliminary design; verify them for your project. Questions or a correction: [email protected].