M-N interaction diagram of an RC column (Eurocode 2): worked example

Key points of the M-N interaction diagram of a 400 x 400 mm C30/37 column by hand to SIST EN 1992-1-1:2024 (parabola-rectangle): pure compression, balanced point, pure bending, MRd at NEd.

 Open this example in the tool The link loads all inputs below.

Problem

A 400 × 400 mm column in C30/37 concrete has three Ø20 B500 bars on each of the two faces in bending, 50 mm from the face to the bar centres. At the base it carries a permanent axial force NEk = −1000 kN (compression) and a moment MEk = 130 kNm. Draw the M-N interaction diagram to SIST EN 1992-1-1:2024 and check the design forces.

Section b × h400 × 400 mm
ConcreteC30/37, γC = 1.5, ktc = 0.85
Reinforcement3 Ø20 top + 3 Ø20 bottom, As = 9.42 cm² per face, a = 50 mm (d = 350 mm)
SteelB500, γS = 1.15, Es = 200 GPa
Characteristic forcesNEk = −1000 kN, MEk = 130 kNm (permanent, γG = 1.35)

Signs follow the tool: compression is negative, and a positive moment compresses the top face. Moments are taken about the centre of the section (200 mm from each face).

1. Design strengths

ηcc = (fck,ref / fck)1/3 = (40 / 30)1/3 = 1.10 → capped at 1.0 (5.4)
fcd = ηcc ktc fck / γC = 1.0 · 0.85 · 30 / 1.5 = 17.0 MPa (5.3)
fyd = 500 / 1.15 = 434.8 MPa,   εyd = 434.8 / 200 000 = 2.174 ‰
one face of bars yielding: Fs,y = 942 · 434.8 = 409.6 kN

The concrete follows the parabola-rectangle diagram (8.1.2) with εc2 = 2.0 ‰ and εcu = 3.5 ‰. When the top fibre is at εcu and the neutral axis is at depth x, the compression block can be replaced by its resultant:

Fc = α fcd b x,   α = 1 − εc2 / (3 εcu) = 1 − 2 / 10.5 = 0.8095
acting at β x from the top,   β = 0.416 (the centroid of the rectangle over 0.429 x plus the parabola below it)
α fcd b = 0.8095 · 17.0 · 400 = 5504.8 N/mm = 5.505 kN per mm of x

The tool integrates the same stress-strain law in 400 thin layers, so it needs no α and β. Comparing the two is a good check of both.

2. Pure compression

The whole section is at εc2 = 2.0 ‰. The steel at this strain carries 200 000 · 0.002 = 400 MPa, which is below fyd:

NRd = −(b h fcd + As,tot · 400) = −(400 · 400 · 17.0 + 1884 · 400) = −(2720.0 + 753.6) = −3474 kN

Like the tool, this uses the gross concrete area and does not subtract the area of the bars. With the minimum eccentricity e0 = max(h/30; 20 mm) = 20 mm (8.1.1(5)), the top of the diagram is cut where M = 0.02 |N|. The tool finds that level at NRd,max = −3114 kN.

3. Pure tension

NRd = As,tot fyd = 2 · 409.6 = +819 kN

4. Balanced point

The top fibre reaches εcu = 3.5 ‰ while the bottom bars just yield at εyd = 2.174 ‰:

x = d · εcu / (εcu + εyd) = 350 · 3.5 / 5.674 = 215.9 mm
top bars: εs2 = 3.5 ‰ · (215.9 − 50) / 215.9 = 2.69 ‰ > εyd → yield, 409.6 kN in compression
Fc = 5.505 · 215.9 = 1188.5 kN, lever arm to the centre 200 − 0.416 · 215.9 = 110.2 mm
NRd = −1188.5 − 409.6 + 409.6 = −1188 kN
MRd = 1188.5 · 0.1102 + 409.6 · 0.150 + 409.6 · 0.150 = 131.0 + 61.4 + 61.4 = 253.8 kNm

This is the nose of the diagram: the largest moment the column can take.

5. Pure bending (N = 0)

Assume the bottom bars yield and the top bars stay elastic, with σs2 = 700 (x − 50) / x MPa. Equilibrium, Fc + Fs2 − Fs1 = 0, in N and mm:

5504.8 x + 942 · 700 (x − 50) / x − 409 565 = 0  →  5504.8 x² + 249 835 x − 32 970 000 = 0
x = 57.96 mm,   σs2 = 700 · 7.96 / 57.96 = 96.1 MPa (elastic, as assumed),   Fs2 = 90.5 kN
bottom bars: εs1 = 3.5 ‰ · (350 − 58) / 58 = 17.6 ‰ > εyd (yield, as assumed)
Fc = 5.505 · 57.96 = 319.1 kN; check: −319.1 − 90.5 + 409.6 = 0 ✓
MRd = 319.1 · (0.200 − 0.416 · 0.0580) + 90.5 · 0.150 + 409.6 · 0.150 = 56.1 + 13.6 + 61.4 = 131.1 kNm

6. Design forces and their check

The axial force is a permanent action that is multiplied by γG, but up to the balanced point more compression also means more moment capacity. EN 1990 therefore needs two combinations: everything × 1.35, and the compressive force as favourable × 1.0. The tool plots both:

A: NEd = 1.35 · (−1000) = −1350 kN,   MEd = 1.35 · 130 = 175.5 kNm
B: NEd = 1.0 · (−1000) = −1000 kN,   MEd = 175.5 kNm

B, N = −1000 kN. With less compression than at the balanced point (|N| < 1188 kN), both faces of bars yield, so their forces cancel and the concrete alone carries N:

x = 1000 / 5.505 = 181.7 mm;   εs2 = 2.54 ‰, εs1 = 3.24 ‰, both > εyd ✓
MRd = 1000 · (0.200 − 0.416 · 0.1817) + 2 · 61.4 = 124.4 + 122.9 = 247.3 kNm  →  MEd / MRd = 0.71

A, N = −1350 kN. Now the top bars yield and the bottom bars stay elastic, with σs1 = 700 (350 − x) / x MPa:

5504.8 x + 409 565 − 942 · 700 (350 − x) / x = 1 350 000  →  5504.8 x² − 281 035 x − 230 790 000 = 0
x = 231.9 mm,   σs1 = 700 · 118.1 / 231.9 = 356.6 MPa,   Fs1 = 335.9 kN,   Fc = 1276.4 kN
MRd = 1276.4 · (0.200 − 0.416 · 0.2319) + 61.4 + 335.9 · 0.150 = 132.2 + 61.4 + 50.4 = 244.0 kNm  →  MEd / MRd = 0.72

Utilisation in the tool. The tool reports η as the distance from the origin to the design point, divided by the distance to the diagram along the same ray (M and N grow in proportion). For A, the ray reaches the diagram at (175.5, −1350) / η. Trying η = 0.794 gives the point (221.0, −1700). With the same steps as above, N = −1700 kN gives x = 269.9 mm and MRd = 221.1 kNm, so the point lies on the diagram and ηA = 0.79. For B the same check gives ηB = 0.72. The column is adequate in bending with axial force. Check shear separately (the tool's Shear tab), and slenderness and second-order effects for the column as a whole.

Result in the tool

Hand calculationToolDifference
fcd / fyd17.0 / 434.8 MPa17.00 / 435 MPa0 %
Pure compression NRd−3474 kN−3474 kN0 %
NRd,max with e0 = 20 mm–−3114 kN
Pure tension NRd+819 kN+819 kN0 %
Balanced point (N / M)−1188 kN / 253.8 kNm−1188 kN / 253.8 kNm0 %
Pure bending MRd131.1 kNm131.1 kNm0 %
MRd at N = −1000 kN247.3 kNm247.3 kNm0 %
MRd at N = −1350 kN244.0 kNm244.0 kNm0 %
ηmax (combination A)0.790.790 %

The link at the top opens the tool with this section and the load pasted as an Excel row. The diagram shows the characteristic point and both design points inside the resistance, with ηmax = 0.79 in the verification card.

Your own case

  • Paste many load cases at once from Excel (columns MEk, NEk, optional Text), or straight from ZSoil, DIANA or RS2 results. Every point is checked and the worst η is reported.
  • For a column that is loaded young, set the concrete age t. The tool then uses fck(t) to SIST EN 1992-1-1:2024 Annex B.
  • The fib Model Code 2020 uses the same parabola-rectangle law (εc2 = 2.0 ‰, εcu2 = 3.5 ‰ for normal strength concrete), so the shape of the diagram is the same. Only the definition of fcd differs.
  • For a tunnel lining or a slab, enter b = 100 cm and the bars per metre. The forces are then per metre.

References

  • SIST EN 1992-1-1:2024 (= EN 1992-1-1:2023), Eurocode 2: Design of concrete structures, Part 1-1, clauses 5.1.6, 5.2.4, 8.1.1 and 8.1.2.
  • EN 1990:2002 + A1:2005, Basis of structural design, 6.4.3 and Annex A.
  • fib Model Code for Concrete Structures 2020. International Federation for Structural Concrete, Lausanne, 2023.

Worked example by Martin Hostnik, updated 2026-11-21. Results are for checking and preliminary design; verify them for your project. Questions or a correction: [email protected].