RC beam shear to SIST EN 1992-1-1:2024: worked example
Shear of a 300 x 500 mm C30/37 beam by hand: resistance without links by the new formula (8.27) with the shear span, then links (8.42), the strut check (8.44) and the minimum ratio (12.4).
Open this example in the tool The link loads all inputs below.
Problem
A simply supported RC beam, 300 × 500 mm, spans 6 m and carries a permanent load gk = 44 kN/m. Check the shear 0.5 m from the support, about d from its face. Does the concrete alone carry it, and if not, which links are needed?
| Section | bw = 300 mm, h = 500 mm |
| Concrete | C30/37, γC = 1.5, ktc = 0.85, aggregate Dlower = 16 mm |
| Longitudinal bars | 3 Ø20 bottom (942 mm²), centroid 50 mm from the face, so d = 450 mm; 2 Ø12 top |
| Links | B500, ductility class B, 2 legs |
| Actions at x = 0.5 m | VEk = 132 − 44 · 0.5 = 110 kN, MEk = 132 · 0.5 − 44 · 0.5² / 2 = 60.5 kNm, N = 0 |
| Design values (γG = 1.35) | VEd = 148.5 kN, MEd = 81.68 kNm |
The rules are those of SIST EN 1992-1-1:2024 (= EN 1992-1-1:2023), clause 8.2. Its resistance without links comes from the critical shear crack theory (Muttoni & Fernández Ruiz 2008), and replaces the CRd,c formula of the 2004 edition. Clause and equation numbers are those of the standard.
1. Parameters
2. Resistance without links
The new formula takes the shear span into account: close to a support, where M / V is small, the shear crack is short and the beam carries more.
For comparison: with av = d (far from the support), τ = 0.4714 · (669.9 / 450)1/3 = 0.538 MPa, which falls below τRdc,min, so VRd,c = 0.550 · 300 · 405 = 66.9 kN. The 2004 edition (6.2.a) gives 0.12 · 1.667 · (0.698 · 30)1/3 · 300 · 450 = 74.4 kN for this section, whatever the shear span.
3. Links
With links the concrete contribution is dropped and a truss carries the shear (8.2.3). Without axial force cot θ = 2.5 (8.2.3(4)).
Two-legged Ø8 links at 250 mm give 2 · 50.3 / 0.25 = 4.02 cm²/m (ρw = 0.134 %), more than the 3.37 cm²/m needed and within sl,max:
Result in the tool
| Hand calculation | Tool | Difference | |
|---|---|---|---|
| d / z, ρl | 450 / 405 mm, 0.698 % | 45.0 / 40.5 cm, 0.70 % | 0 % |
| τRdc,min | 0.550 MPa | 0.550 MPa | 0 % |
| τEd / τRd,c | 1.222 / 0.656 MPa | 1.222 / 0.656 MPa | 0 % |
| VEd / VRd,c, η | 148.5 / 79.7 kN, 1.86 | 148.5 / 79.7 kN, 1.86 | 0 % |
| Links required / minimum | 3.37 / 2.37 cm²/m | 3.37 / 2.37 cm²/m | 0 % |
| Compression field | 3.54 ≤ 8.50 MPa | 3.54 ≤ 8.50 MPa | 0 % |
| Proposed links | Ø8 / 25 cm = 4.02 cm²/m | Φ8 / 25 cm = 4.02 cm²/m | |
| VRd,s / η | 177.0 kN / 0.84 | 177.0 kN / 0.84 | 0 % |
The link at the top opens the M-N tool on its Shear tab with this section and the characteristic forces pasted as an Excel table (MEk, NEk, VEk). The tool applies γG = 1.35, as set under the results.
Your own case
- Paste every section of the beam, or the results of a whole lining from ZSoil, RS2 or DIANA. The tool checks each point with its own M / V and N, and shows the governing one.
- Axial compression raises the resistance through kvp (8.31), and axial tension lowers it. Choose σcp (8.32) instead if your national annex prefers it.
- For slabs and tunnel linings choose Slab / lining (per m): they need links only where the concrete alone is not enough (Table 12.2).
- Choose your own links under User input to check an existing design.
References
- SIST EN 1992-1-1:2024 (= EN 1992-1-1:2023). Eurocode 2: Design of concrete structures, Part 1-1, clauses 8.2 and 12.2.
- Muttoni, A. & Fernández Ruiz, M. (2008). Shear strength of members without transverse reinforcement as function of critical shear crack width. ACI Structural Journal 105(2), 163–172.
- EN 1992-1-1:2004. Eurocode 2: Design of concrete structures, Part 1-1, 6.2.2 (for comparison).
Worked example by Martin Hostnik, updated 2026-11-21. Results are for checking and preliminary design; verify them for your project. Questions or a correction: [email protected].