M-N interaction diagram

Rectangular and circular reinforced concrete sections and fibre reinforced concrete to SIST EN 1992-1-1:2024 (= EN 1992-1-1:2023) incl. Annex L, and fib Model Code 2020.

Worked example: RC column M-N · Worked example: RC beam shear

Section & concrete
bcm
hcm
fckMPa
γc-
ktc
td
Class
Advanced
Reinforcement
As,topcm2
as,topcm
As,botcm2
as,botcm
fykMPa
γs-
EsGPa
Shear
γV-
Dlowermm
N effect
d and Asl from the tension side of each point; acs = |MEd/VEd| ≥ d (8.30).
Links
Legs
fywkMPa
Class-
Loads
γG-
factor-
M-N pair
Loading...
Reinforced Concrete – M-N Interaction Diagram
Shear Check
Project information
Name
Description
Paste results · Excel, ZSoil, Rocscience RS2, DIANA
Excel: tab separated columns MEk, NEk (optional VEk, MEd_SF, NEd_SF, VEd_SF, X, Y, Stage, Text). N < 0 = compression.
Design basis
  • Standard: SIST EN 1992-1-1:2024, the Slovenian adoption of EN 1992-1-1:2023 (second-generation Eurocode 2); clause and formula numbers are identical.
  • Bending with axial force: SIST EN 1992-1-1:2024, 8.1 – plane sections, parabola-rectangle stress block (8.1.2, εc2 = 2‰, εcu = 3.5‰, pivot at εc2), concrete tensile strength ignored, reinforcement elastic-perfectly plastic with a horizontal branch and no strain limit (5.2.4(2)b), fcd = ηccktcfck/γC (5.3)/(5.4), minimum eccentricity e0 = max(h/30; 20 mm) (8.1.1(5)).
  • Steel fibres: SIST EN 1992-1-1:2024 Annex L – fFtud = κOκG·0.33fR,3k/γSF (rigid-plastic, L.3/L.5) or fFt1d = κOκG·0.37fR,1k/γSF, fFt3d = κOκG(0.57fR,3k − 0.26fR,1k)/γSF (bilinear, L.8.1(3)); or fib Model Code 2020.
  • Synthetic fibres (not covered by EC2 Annex L): fib Model Code 2020, 18.4.2 – fFtu = fR,3k/3 (rigid-plastic) or fFts = 0.37fR,1k, fFtu = fFts − (wu − CMOD1)/(CMOD3 − CMOD1)·(fFts − 0.57fR,3k + 0.26fR,1k); fFtud = κOκGfFtu/γF; creep factor ηcreep (18.2.2); no durability layer. ÖBV RL Spritzbeton (2025) checks are shown as warnings.
  • Softening tension laws: by default the resistance is the limit-state loop with the ULS strain εFtu at the tension face (EC2 L.8.1(3), MC2020 wu). Optionally (Advanced) the envelope of all admissible plane strain states.
  • Shear (Shear tab): SIST EN 1992-1-1:2024 8.2.2 τRd,c (8.27) with acs = |MEd/VEd| ≥ d (8.29)/(8.30) and kvp (8.31) or σcp (8.32), ≥ τRdc,min (8.20); links 8.2.3 (8.42), cot θ = 2.5 (lower down to 1.0 where the compression field governs), compression field (8.44) limiting VRd, minimum (12.4) with 12.2(4) ductility class, 12.2(5) members in compression, Table 12.2 slabs only where links are required, Annex L (L.31) with fibres, spacing Tables 12.1/12.2; circular sections bw = Dh (8.2.3(9)). Steel fibres with bars: Annex L (L.19)-(L.21); without bars, or with the fib approach: fib MC2020 30.1.3.4 Level II (30.1-54)-(30.1-66) with fFTU at wu = 2 mm (30.1-63). Fibres are ignored for points in axial tension.
  • κO defaults to 0.5 for EC2 (L.5.5.1(3), also sprayed concrete) and 1.0 for fib MC2020 (18.5, quasi-isotropic).
  • Nationally determined parameters (γC, γV, fck,ref, ktc, γS, γSF, εFtud, ...) are inputs and have to be chosen according to the relevant National Annex.

About this tool

Draws the design M-N interaction diagram of a rectangular reinforced concrete section (or a slab strip per metre) and plots the internal forces of your structural analysis on it, so you can see at once which points lie inside the capacity curve.

Inputs are the section width and height, concrete strength f_ck with the partial factor γ_c, η_cc and k_tc (SIST EN 1992-1-1:2024 5.1.6), top and bottom reinforcement with cover, and steel f_yk, γ_s and E_s. The minimum eccentricity e0 = max(h/30; 20 mm) can be applied. Partial factors are left to the user so they can follow the National Annex.

The Shear tab checks members without and with shear reinforcement to SIST EN 1992-1-1:2024 8.2: τ_Rd,c from (8.27) with the mechanical shear span, the axial force effect, the minimum τ_Rdc,min, and links (2, 4 or 6 legs, diameter and spacing) with the compression field check.

Load results can be pasted from Excel, ZSoil, Rocscience RS2 or DIANA (for example shotcrete lining elements of a tunnel stage). The diagram, the points and a report can be copied or exported.

Which standards does the M-N tool use?

SIST EN 1992-1-1:2024 (the Slovenian adoption of EN 1992-1-1:2023, same content and clause numbers) for reinforced concrete bending, axial force and shear; fib Model Code 2020 and SIST EN 1992-1-1:2024 Annex L for fibre reinforced concrete.

Can I check a tunnel lining from FE results?

Yes. Paste the liner element forces from ZSoil, RS2 or DIANA; each element end and mid point is plotted as an M-N pair and checked for shear.

Worked example

Related tools

Free to use, no sign-up. Results are for checking and preliminary design; verify them for your project. Questions or ideas: [email protected].