M-N interaction diagram
Rectangular and circular reinforced concrete sections and fibre reinforced concrete to SIST EN 1992-1-1:2024 (= EN 1992-1-1:2023) incl. Annex L, and fib Model Code 2020.
Loads
Design basis
- Standard: SIST EN 1992-1-1:2024, the Slovenian adoption of EN 1992-1-1:2023 (second-generation Eurocode 2); clause and formula numbers are identical.
- Bending with axial force: SIST EN 1992-1-1:2024, 8.1 – plane sections, parabola-rectangle stress block (8.1.2, εc2 = 2‰, εcu = 3.5‰, pivot at εc2), concrete tensile strength ignored, reinforcement elastic-perfectly plastic with a horizontal branch and no strain limit (5.2.4(2)b), fcd = ηccktcfck/γC (5.3)/(5.4), minimum eccentricity e0 = max(h/30; 20 mm) (8.1.1(5)).
- Steel fibres: SIST EN 1992-1-1:2024 Annex L – fFtud = κOκG·0.33fR,3k/γSF (rigid-plastic, L.3/L.5) or fFt1d = κOκG·0.37fR,1k/γSF, fFt3d = κOκG(0.57fR,3k − 0.26fR,1k)/γSF (bilinear, L.8.1(3)); or fib Model Code 2020.
- Synthetic fibres (not covered by EC2 Annex L): fib Model Code 2020, 18.4.2 – fFtu = fR,3k/3 (rigid-plastic) or fFts = 0.37fR,1k, fFtu = fFts − (wu − CMOD1)/(CMOD3 − CMOD1)·(fFts − 0.57fR,3k + 0.26fR,1k); fFtud = κOκGfFtu/γF; creep factor ηcreep (18.2.2); no durability layer. ÖBV RL Spritzbeton (2025) checks are shown as warnings.
- Softening tension laws: by default the resistance is the limit-state loop with the ULS strain εFtu at the tension face (EC2 L.8.1(3), MC2020 wu). Optionally (Advanced) the envelope of all admissible plane strain states.
- Shear (Shear tab): SIST EN 1992-1-1:2024 8.2.2 τRd,c (8.27) with acs = |MEd/VEd| ≥ d (8.29)/(8.30) and kvp (8.31) or σcp (8.32), ≥ τRdc,min (8.20); links 8.2.3 (8.42), cot θ = 2.5 (lower down to 1.0 where the compression field governs), compression field (8.44) limiting VRd, minimum (12.4) with 12.2(4) ductility class, 12.2(5) members in compression, Table 12.2 slabs only where links are required, Annex L (L.31) with fibres, spacing Tables 12.1/12.2; circular sections bw = Dh (8.2.3(9)). Steel fibres with bars: Annex L (L.19)-(L.21); without bars, or with the fib approach: fib MC2020 30.1.3.4 Level II (30.1-54)-(30.1-66) with fFTU at wu = 2 mm (30.1-63). Fibres are ignored for points in axial tension.
- κO defaults to 0.5 for EC2 (L.5.5.1(3), also sprayed concrete) and 1.0 for fib MC2020 (18.5, quasi-isotropic).
- Nationally determined parameters (γC, γV, fck,ref, ktc, γS, γSF, εFtud, ...) are inputs and have to be chosen according to the relevant National Annex.
Found this tool useful?
koplemo is free, with no ads and no sign-up. It is kept running by the engineers who use it.
Payment handled by Stripe. We never see your card details.
Payment handled by Stripe. You can cancel at any time; write to [email protected] if you need help.
About this tool
Draws the design M-N interaction diagram of a circular reinforced concrete section with bars evenly spaced around the perimeter, typical of bored piles, diaphragm wall piles and columns, and plots your design forces on it.
Inputs are the diameter, concrete strength and partial factors, the number and diameter of bars and their cover. Results can be pasted from Excel, ZSoil, RS2 or DIANA.
The shear check follows SIST EN 1992-1-1:2024 8.2 with b_w = D_h and the tension chord from 8.2.3(9), with or without circular links.
Can I use it for a bored pile?
Yes. Enter the pile diameter and its longitudinal bars; the axial force and bending moment from a pile or retaining wall analysis can be pasted directly.
Worked example
Related tools
Free to use, no sign-up. Results are for checking and preliminary design; verify them for your project. Questions or ideas: [email protected].